Detroit DD13 EPA07 (2007-09) Fault Code: SPN 3512 FMI 3 (MCM) 3V Sensor Supply Bank 1 Circuit Failed High
NOTE: This fault indicates that the motor control module (MCM) detects a short to power (voltage greater than 3.2. on any of the MCM pins).
PROBABLE CAUSES:
Short to power on one of the following from the main 120-pin ECM connector:
1. Pin 55 - Fuel temp sensor, engine coolant temp sensor.
2. Pin 77 - Fuel temp sensor.
3. Pin 102 - Charge air cooler outlet pressure sensor.
4. Pin 108 - Engine oil temperature/pressure sensor.
5. Pin 110 - Engine coolant temperature sensor.
Detroit DD13 EPA07 (2007-09) Fault Code: SPN 3511 FMI 3 (MCM) 3V Sensor Supply Bank 1 Circuit Failed High
Detroit DD13 EPA07 (2007-09) Fault Code: SPN 3510 FMI 8 (CPC) 2-Channel Accelerator Pedal Supply Voltage Missing
Detroit DD13 EPA07 (2007-09) Fault Code: SPN 3510 FMI 7 (CPC) Accelerator Pedal Sensor Failed High
Detroit DD13 EPA07 (2007-09) Fault Code: SPN 3510 FMI 4 (CPC) Accelerator Pedal Supply Voltage Circuit Failed Low