Detroit DD13 EPA07 (2007-09) Fault Code: SPN 3480 FMI 14 (MCM) Hydrocarbon Doser Fuel Line Pressure Sensor - Failed Self Test
DESCRIPTION:
Hydrocarbon (HC) doser fuel line pressure (FLP) sensors-failed self test.
MONITORED PARAMETER:
Doser fuel line pressure.
TYPICAL ENABLING CONDITIONS:
Dosing enabled
MONITOR SEQUENCE:
None
EXECUTION FREQUENCY:
Continuous when enabling conditions met.
TYPICAL DURATION:
One minute
DASH LAMPS:
1. MIL
2. CEL
ENGINE REACTION:
Derate 10%
VERIFICATION:
Parked regeneration
PROBABLE CAUSES:
1. Replace the fuel compensation pressure sensor.
2. Perform stationary regen.
Detroit DD13 EPA07 (2007-09) Fault Code: SPN 3480 FMI 4 (MCM) Fuel Compensation Pressure Sensor Circuit Failed Low
Detroit DD13 EPA07 (2007-09) Fault Code: SPN 3480 FMI 3 (MCM) Fuel Compensation Pressure Sensor Circuit Failed High
Detroit DD13 EPA07 (2007-09) Fault Code: SPN 3480 FMI 2 (MCM) Hydrocarbon Doser Fuel Line Pressure Low
Detroit DD13 EPA07 (2007-09) Fault Code: SPN 3480 FMI 1 (MCM) Hydrocarbon Doser Fuel Supply Pressure Abnormal