Detroit DD13 EPA07 (2007-09) Fault Code: SPN 2630 FMI 3 (MCM) Charger Air Cooler Outlet Temperature Circuit Failed High
DESCRIPTION:
Charge air cooler (CAC) short to voltage or open.
MONITORED PARAMETER:
CAC outlet temperature sensor.
TYPICAL ENABLING CONDITIONS:
Always enabled
MONITOR SEQUENCE:
None
EXECUTION FREQUENCY:
Always enabled
TYPICAL DURATION:
Two seconds
DASH LAMPS:
CEL
ENGINE REACTION:
None
VERIFICATION:
Engine Idle: One minute.
PROBABLE CAUSES:
1. Intake manifold air temperature sensor failure.
2. Intake manifold air temperature sensor harness/connector.
Detroit DD13 EPA07 (2007-09) Fault Code: SPN 2630 FMI 2 (MCM) Engine Air Temperature Plausibility Fault Out of Range (High Box)
Detroit DD13 EPA07 (2007-09) Fault Code: SPN 2623 FMI 14 (CPC) 2 - Channel Accelerator Pedal GAS1 and GAS2 Signal Missing
Detroit DD13 EPA07 (2007-09) Fault Code: SPN 2623 FMI 4 (CPC) PWM Accelerator Pedal J1939 GAS2 Signal is Missing
Detroit DD13 EPA07 (2007-09) Fault Code: SPN 1845 FMI 9 (CPC) TCFG2 Message is Missing