Detroit DD13 EPA07 (2007-09) Fault Code: SPN 1077 FMI 5 (MCM) Quantity Control Valve Current Too Low
DESCRIPTION:
Quantity control valve (QCV) error.
MONITORED PARAMETER:
Quantity control valve.
TYPICAL ENABLING CONDITIONS:
RP closed loop control.
MONITOR SEQUENCE:
None
EXECUTION FREQUENCY:
Current less than 200 mA.
TYPICAL DURATION:
Two seconds
DASH LAMPS:
1. MIL
2. CEL
ENGINE REACTION:
Derate 25%
VERIFICATION:
Engine Idle: One minute.
PROBABLE CAUSES:
1. Wiring between the ECM and the quantity control valve.
2. Quantity control valve.
Detroit DD13 EPA07 (2007-09) Fault Code: SPN 1073 FMI 5 (MCM) Jake Brake Stage 2 Circuit Failed Open
Detroit DD13 EPA07 (2007-09) Fault Code: SPN 1073 FMI 4 (MCM) Jake Brake Stage 2 Circuit Failed Low
Detroit DD13 EPA07 (2007-09) Fault Code: SPN 1073 FMI 3 (MCM) Jake Brake Stage 2 Circuit Failed High
Detroit DD13 EPA07 (2007-09) Fault Code: SPN 1072 FMI 5 (MCM) Jake Brake Stage 1 Circuit Failed Open