Detroit DD13 EPA07 (2007-09) Fault Code: SPN 705 FMI 3 (MCM) Digital Output 1 13 Circuit Failed High
DESCRIPTION:
CPC output 1 13 short to voltage.
MONITORED PARAMETER:
CPC output 1/13.
TYPICAL ENABLING CONDITIONS:
Always enabled
MONITOR SEQUENCE:
None
EXECUTION FREQUENCY:
Always enabled
TYPICAL DURATION:
Two seconds
DASH LAMPS:
CEL
ENGINE REACTION:
None
VERIFICATION:
Engine on with output activation.
NOTE: Pin 13 of the CPC #1 connector has a wiring problem.