Detroit DD15 EPA10 (2010-13) Fault Code: SPN 1663 FMI 7 (MCM, CPC, ACM) Optimized Idle Safety Loop Faulted
DESCRIPTION:
Optimized idle safety loop faulted.
MONITORED PARAMETER:
Optimized idle safety loop (parking brake, hood tilt switch, neutral safety switch and vehicle speed).
TYPICAL ENABLING CONDITIONS:
Fault is set active is a maximum number of vehicle speed sensor pulses during and optimized idle engine start is exceeded or the vehicle speed is above 0.25 km/h or the engine torque is above a calibrated threshold for 2 seconds.
MONITOR SEQUENCE:
None
DASH LAMPS:
CEL
ENGINE REACTION:
None
VERIFICATION:
Run an optimized idle mode.
NOTE: Vehicle speed sensor failure.