Detroit DD16 EPA10 (2010-13) Fault Code: SPN 111 FMI 3 (CPC) Coolant Level Circuit Failed High
DESCRIPTION:
Coolant level circuit signal above normal range.
MONITORED PARAMETER:
Coolant level
TYPICAL ENABLING CONDITIONS:
Always on
MONITOR SEQUENCE:
None
EXECUTION FREQUENCY:
Continuous when enabling conditions met.
TYPICAL DURATION:
Two seconds
DASH LAMPS:
CEL
ENGINE REACTION:
None
VERIFICATION:
Cycle key
NOTE: If any other active fault codes, fix those first.
PROBABLE CAUSES:
1. Low coolant.
2. Coolant level sensor connector/harness.
3. Coolant level sensor.
4. Cooling system leaks.
5. Radiator cap failure.