Detroit DD15 GHG14 (2014-16) Fault Code: SPN 3471 FMI 5 (MCM) Hydrocarbon Doser Circuit Failed Open
DESCRIPTION:
Hydrocarbon (HC) doser circuit failed open.
MONITORED PARAMETER:
HC doser circuit.
TYPICAL ENABLING CONDITIONS:
Always enabled
MONITOR SEQUENCE:
None
EXECUTION FREQUENCY:
Always enabled
TYPICAL DURATION:
Two seconds
DASH LAMPS:
1. MIL
2. CEL
ENGINE REACTION:
Derate 10%
VERIFICATION:
Engine idle
PROBABLE CAUSES:
1. Wiring between the EDV and the 120-pin ECM connection.
2. Metering unit failure.
3. Electronic dosing valve failure.
Detroit DD15 GHG14 (2014-16) Fault Code: SPN 3471 FMI 4 (MCM) Hydrocarbon Doser Circuit Failed Low
Detroit DD15 GHG14 (2014-16) Fault Code: SPN 3471 FMI 3 (MCM) Hydrocarbon Electronic Dosing Valve Circuit Failed High
Detroit DD15 GHG14 (2014-16) Fault Code: SPN 3471 FMI 1 (MCM) Electronic Dosing Valve Failed Self Test
Detroit DD15 GHG14 (2014-16) Fault Code: SPN 3364 FMI 18 (ACM) Improper Diesel Exhaust Fluid Quality Warning