Eaton Fuller Advantage (2017) Fault Code: 63 PID: SID 40 SPN: FMI: 6 Gear Motor Circuit: Current Above Normal or Shorted Circuit
Overview:
The Fuller Advantage Transmission is equipped with an X-Y Shifter that selects a transmission gear. The X-Y Shifter motors are controlled with electrical current supplied by the TECU to move the Shift Finger either side-to-side (rail selection) or fore-and-aft (gear engagement and disengagement). Fault Code 63 indicates a failure of the circuit controlling the Gear Motor and the fore-and-aft movement of the X-Y Shift Finger.
Detection:
The system can identify an issue with the X-Y Shifter Gear Motor circuit, the TECU gear motor controller or the power and ground connections to the TECU under the following conditions:
FMI 6 can be detected when the X-Y Gear Motor is not energized
Conditions to Set Fault Code Active:
FMI 6 Current Above Normal or Shorted Circuit: TECU detects a short to power on the Gear Motor circuit for 0.5 seconds at power up or prior to a shift.
Fallback:
All FMIs
F flashes in gear display.
Service light flashes (if equipped).
Engine may not crank.
Transmission may not engage a gear from neutral.
Transmission does not shift while the vehicle is moving.
Until the fault becomes Inactive, driver may have to shut off engine with transmission in gear.
Conditions to Set Fault Code Inactive:
FMI 6: An electrical short or open circuit is not detected for 0.5 seconds
Possible Causes:
FMI 6
1) Transmission Harness
- Wiring shorted to power
2) TECU
- Internal failure