CAT 3406E (Prefix 5DS or 1LW) Fault Code: 26 PID: 108 SPN: FMI: 4 Barometric Pressure voltage low
The Engine Control Module (ECM) detects the following conditions:
The signal voltage from the atmospheric pressure sensor is less than 0.2 VDC for more than 30 seconds.
The ECM has been powered for at least two seconds.
The engine is not running or the engine has been running for more than ten seconds.
Probable Causes:
1) ECM Connection/Harness
2) Crankcase breather plugged
3) Pressure sensor
4) Pressure sensor harness
5) ECM Failure
CAT 3406E (Prefix 5DS or 1LW) Fault Code: 26 PID: 108 SPN: FMI: 3 Barometric Pressure voltage high
CAT 3406E (Prefix 5DS or 1LW) Fault Code: 25 PID: 102 SPN: FMI: 4 Boost Pressure voltage low
CAT 3406E (Prefix 5DS or 1LW) Fault Code: 25 PID: 102 SPN: FMI: 3 Boost Pressure voltage high
CAT 3406E (Prefix 5DS or 1LW) Fault Code: 25 PID: 102 SPN: FMI: 0 Excessive Boost Pressure