CAT 3406E (Prefix 5DS or 1LW) Fault Code: 25 PID: 102 SPN: FMI: 4 Boost Pressure voltage low
The Engine Control Module (ECM) detects the following conditions:
The signal voltage from the boost pressure sensor is greater than 4.95 VDC for more than two seconds.
The ECM has been powered for at least two seconds.
The engine is not running or the rack position is less than 50 percent with the engine retarder off.
Probable Causes:
1) ECM Connection/Harness
2) Crankcase breather plugged
3) Pressure sensor
4) Pressure sensor harness
5) ECM Failure
CAT 3406E (Prefix 5DS or 1LW) Fault Code: 25 PID: 102 SPN: FMI: 3 Boost Pressure voltage high
CAT 3406E (Prefix 5DS or 1LW) Fault Code: 25 PID: 102 SPN: FMI: 0 Excessive Boost Pressure
CAT 3406E (Prefix 5DS or 1LW) Fault Code: 24 PID: 100 SPN: FMI: 4 Oil Pressure voltage low
CAT 3406E (Prefix 5DS or 1LW) Fault Code: 24 PID: 100 SPN: FMI: 3 Oil Pressure voltage high
If you want to know other articles similar to CAT 3406E (Prefix 5DS or 1LW) Fault Code: 25 PID: 102 SPN: FMI: 4 Boost Pressure voltage low you can visit the category 3406E (Prefix 5DS or 1LW).