CAT 3406E (Prefix 5DS or 1LW) Fault Code: 26 PID: 108 SPN: FMI: 3 Barometric Pressure voltage high
The Engine Control Module (ECM) detects the following conditions:
The signal voltage from the atmospheric pressure sensor is greater than 4.9 VDC for more than 30 seconds.
The ECM has been powered for at least two seconds.
Probable Causes:
1) ECM Connection/Harness
2) Crankcase breather plugged
3) Pressure sensor
4) Pressure sensor harness
5) ECM Failure
CAT 3406E (Prefix 5DS or 1LW) Fault Code: 25 PID: 102 SPN: FMI: 4 Boost Pressure voltage low
CAT 3406E (Prefix 5DS or 1LW) Fault Code: 25 PID: 102 SPN: FMI: 3 Boost Pressure voltage high
CAT 3406E (Prefix 5DS or 1LW) Fault Code: 25 PID: 102 SPN: FMI: 0 Excessive Boost Pressure
CAT 3406E (Prefix 5DS or 1LW) Fault Code: 24 PID: 100 SPN: FMI: 4 Oil Pressure voltage low
If you want to know other articles similar to CAT 3406E (Prefix 5DS or 1LW) Fault Code: 26 PID: 108 SPN: FMI: 3 Barometric Pressure voltage high you can visit the category 3406E (Prefix 5DS or 1LW).