CAT 3406E (Prefix 5DS or 1LW) Fault Code: 56 PID: 253 SPN: FMI: 11 Check Transmission Customer Parameters

This condition indicates that the "Transmission Style" parameter is programmed to the Eaton Top 2 and any one of the following parameters are not programmed:

•"Auxiliary Output 2" (Multi-Function Output #2) is not programmed to "Shift Solenoid".
•"Auxiliary Output 3" (Multi-Function Output #3) is not programmed to "Lockout Solenoid".
•"Gear Ratios" not programmed

Probable Causes:

Program the "Transmission Style" parameter that is Eaton Top 2 to the correct setting. If an Eaton Top 2 Transmission is not used, program the correct "Transmission Style" parameter to the correct setting.

If you want to know other articles similar to CAT 3406E (Prefix 5DS or 1LW) Fault Code: 56 PID: 253 SPN: FMI: 11 Check Transmission Customer Parameters you can visit the category 3406E (Prefix 5DS or 1LW).