CAT 3406E (Prefix 5DS or 1LW) Fault Code: 69 PID: 26 SPN: FMI: 5 Auxiliary Output #01 current low
The ECM detects the following conditions:
There is a low current condition (open circuit) in auxiliary output 01.
Probable Causes:
1) ECM Connector/harness
2) Shift solenoid failure
3) Shift solenoid relay
4) Wiring between shift solenoid and ECM
5) Gear ratios are programmed incorrectly in the ECM