Cummins ISB6.7 CM2350 (2013-17) Fault Code: 4161 PID: SPN: 5742 FMI: 3 Aftertreatment Diesel Particulate Filter Temperature Sensor Module - Voltage Above Normal, or Shorted to High Source. High battery supply voltage detected at the aftertreatment diesel particulate filter temperature sensor module.
Cummins ISB6.7 CM2350 (2013-17) Fault Code: 4162 PID: SPN: 5742 FMI: 4 Aftertreatment Diesel Particulate Filter Temperature Sensor Module - Voltage below normal, or shorted to low source. Low battery supply voltage detected at the aftertreatment diesel particulate filter temperature sensor module.
Cummins ISB6.7 CM2350 (2013-17) Fault Code: 4163 PID: SPN: 5742 FMI: 16 Aftertreatment Diesel Particulate Filter Temperature Sensor Module- Data Valid But Above Normal Operating Range - Moderately Severe Level. High internal temperature detected in the aftertreatment diesel particulate filter temperature sensor module.
Cummins ISB6.7 CM2350 (2013-17) Fault Code: 4164 PID: SPN: 5743 FMI: 3 Aftertreatment Selective Catalytic Reduction Temperature Sensor Module - Voltage Above Normal, or Shorted to High Source. High battery supply voltage detected at the aftertreatment SCR temperature sensor module.
Cummins ISB6.7 CM2350 (2013-17) Fault Code: 4165 PID: SPN: 5743 FMI: 4 Aftertreatment Selective Catalytic Reduction Temperature Sensor Module - Voltage below normal, or shorted to low source. Low battery supply voltage detected at the aftertreatment SCR temperature sensor module.
Cummins ISB6.7 CM2350 (2013-17) Fault Code: 4166 PID: SPN: 5743 FMI: 16 Aftertreatment Selective Catalytic Reduction Temperature Sensor Module - Data Valid But Above Normal Operating Range - Moderately Severe Level. High internal temperature detected in the aftertreatment SCR temperature sensor module.
Cummins ISB6.7 CM2350 (2013-17) Fault Code: 4168 PID: SPN: 5745 FMI: 3 Aftertreatment Diesel Exhaust Fluid Dosing Unit Heater - Voltage Above Normal, or Shorted to High Source. The aftertreatment diesel exhasut fluid dosing unit heater is detected to be stuck on.
Cummins ISB6.7 CM2350 (2013-17) Fault Code: 4169 PID: SPN: 5745 FMI: 4 Aftertreatment Diesel Exhaust Fluid Dosing Unit Heater - Voltage below normal, or shorted to low source. The aftertreatment diesel exhasut fluid dosing unit heater is detected to be stuck off.
Cummins ISB6.7 CM2350 (2013-17) Fault Code: 4171 PID: SPN: 5745 FMI: 18 Aftertreatment Diesel Exhaust Fluid Dosing Unit Heater - Data Valid But Below Normal Operating Range - Moderately Severe Level. The aftertreatment diesel exhaust fluid dosing unit failed to thaw.
Cummins ISB6.7 CM2350 (2013-17) Fault Code: 4213 PID: SPN: 3695 FMI: 2 Aftertreatment Regeneration Inhibit Switch - Data erratic, intermittent or incorrect. The aftertreatment regeneration permit switch is stuck in the OFF or INHIBIT position.