Cummins ISB6.7 CM2350 (2013-17) Fault Code: 6266 PID: SPN: 5862 FMI: 14 Aftertreatment SCR Intermediate Gas Temperature Sensor - Data erratic, intermittent or incorrect. The aftertreatment SCR intermediate temperature sensor reading is irrational.
Cummins ISB6.7 CM2350 (2013-17) Fault Code: 6267 PID: SPN: 4360 FMI: 14 Aftertreatment SCR Intermediate Gas Temperature Sensor - Data erratic, intermittent or incorrect. The aftertreatment SCR intermediate temperature sensor reading is irrational.
Cummins ISB6.7 CM2350 (2013-17) Fault Code: 6268 PID: SPN: 4363 FMI: 12 Aftertreatment SCR Outlet Temperature Sensor Circuit - Voltage Above Normal or Shorted to High Source. High signal voltage detected at the SCR outlet temperature sensor circuit.
Cummins ISB6.7 CM2350 (2013-17) Fault Code: 6315 PID: SPN: 7418 FMI: 11 Hybrid System OBD Related DTC Status- Root Cause Not Known. Unexpected data link communications between the ECM and the Hybrid system controller have occurred.
Cummins ISB6.7 CM2350 (2013-17) Fault Code: 6339 PID: SPN: 96 FMI: 9 SAE J1939 Multiplexing PGN Timeout Error - Abnormal Update Rate. The ECM expected information from a multiplexed device but did not receive it soon enough or did not receive it at all.
Cummins ISB6.7 CM2350 (2013-17) Fault Code: 6341 PID: SPN: 96 FMI: 13 SAE J1939 Multiplexing Configuration Error - Out of Calibration. The ECM expected information from a multiplexed device but only received a portion of the necessary information.
Cummins ISB6.7 CM2350 (2013-17) Fault Code: 6342 PID: SPN: 38 FMI: 9 SAE J1939 Multiplexing PGN Timeout Error - Abnormal Update Rate. The ECM expected information from a multiplexed device but did not receive it soon enough or did not receive it at all.
Cummins ISB6.7 CM2350 (2013-17) Fault Code: 6343 PID: SPN: 38 FMI: 13 SAE J1939 Multiplexing Configuration Error - Out of Calibration. The ECM expected information from a multiplexed device but only received a portion of the necessary information.
Cummins ISB6.7 CM2350 (2013-17) Fault Code: 6412 PID: SPN: 7315 FMI: 11 Propulsion System Active - Root Cause Not Known. Unexpected data link communications between the ECM and the propulsion system have occurred.
Cummins ISB6.7 CM2350 (2013-17) Fault Code: 6416 PID: SPN: 3703 FMI: 31 Particulate Trap Active Regeneration Inhibited Due to Inhibit Switch - Condition Exists. Regeneration of the diesel particulate filter has been prevented due to the permit switch being disabled.