Cummins ISL CM850 (2003-06) Fault Code: 297 PID: 223 SPN: 1388 FMI: 3 Auxiliary Pressure Sensor Input 1 Circuit - Voltage Above Normal, or Shorted to High Source. High signal voltage detected at the OEM pressure circuit.
Cummins ISL CM850 (2003-06) Fault Code: 297 PID: 223 SPN: 1388 FMI: 3 Auxiliary Pressure Sensor Input 1 Circuit - Voltage Above Normal, or Shorted to High Source. High signal voltage detected at the OEM pressure circuit.
Possible causes:
1)Open return circuit in the harness, connectors, or sensor.
2)signal circuit shorted to sensor supply or battery voltage.
Possible repairs:
1)Replace the OEM pressure sensor.
2)Replace the ECM.
Cummins ISL CM850 (2003-06) Fault Code: 296 PID: 223 SPN: 1388 FMI: 14 Auxiliary Pressure Sensor Input 1 - Special Instructions
Cummins ISL CM850 (2003-06) Fault Code: 295 PID: 108 SPN: 108 FMI: 2 Barometric Pressure ?Data Erratic, Intermittent, or Incorrect. The barometric air pressure sensor is reading an erratic value at initial key-on.
Cummins ISL CM850 (2003-06) Fault Code: 294 PID: 441 SPN: 441 FMI: 4 Auxiliary Temperature Sensor Input 1 Circuit - Voltage Below Normal, or Shorted to Low Source. Low signal voltage detected at OEM auxiliary temperature circuit.
Cummins ISL CM850 (2003-06) Fault Code: 293 PID: 441 SPN: 441 FMI: 3 Auxiliary Temperature Sensor Input 1 - Voltage Above Normal, or Shorted to High Source. High signal voltage or open circuit detected at the OEM auxiliary temperature circuit.
If you want to know other articles similar to Cummins ISL CM850 (2003-06) Fault Code: 297 PID: 223 SPN: 1388 FMI: 3 Auxiliary Pressure Sensor Input 1 Circuit - Voltage Above Normal, or Shorted to High Source. High signal voltage detected at the OEM pressure circuit. you can visit the category Cumminz.