Cummins ISL CM850 (2003-06) Fault Code: 298 PID: 223 SPN: 1388 FMI: 4 Auxiliary Pressure Sensor Input 1 Circuit - Voltage Above Normal, or Shorted to High Source. High signal voltage detected at the OEM pressure circuit.
Cummins ISL CM850 (2003-06) Fault Code: 298 PID: 223 SPN: 1388 FMI: 4 Auxiliary Pressure Sensor Input 1 Circuit - Voltage Above Normal, or Shorted to High Source. High signal voltage detected at the OEM pressure circuit.
Possible causes:
1)Open return circuit in the harness, connectors, or sensor.
2)signal circuit shorted to sensor supply or battery voltage.
Possible repairs:
1)Replace the OEM pressure sensor.
2)Replace the ECM.
Cummins ISL CM850 (2003-06) Fault Code: 297 PID: 223 SPN: 1388 FMI: 3 Auxiliary Pressure Sensor Input 1 Circuit - Voltage Above Normal, or Shorted to High Source. High signal voltage detected at the OEM pressure circuit.
Cummins ISL CM850 (2003-06) Fault Code: 296 PID: 223 SPN: 1388 FMI: 14 Auxiliary Pressure Sensor Input 1 - Special Instructions
Cummins ISL CM850 (2003-06) Fault Code: 295 PID: 108 SPN: 108 FMI: 2 Barometric Pressure ?Data Erratic, Intermittent, or Incorrect. The barometric air pressure sensor is reading an erratic value at initial key-on.
Cummins ISL CM850 (2003-06) Fault Code: 294 PID: 441 SPN: 441 FMI: 4 Auxiliary Temperature Sensor Input 1 Circuit - Voltage Below Normal, or Shorted to Low Source. Low signal voltage detected at OEM auxiliary temperature circuit.
If you want to know other articles similar to Cummins ISL CM850 (2003-06) Fault Code: 298 PID: 223 SPN: 1388 FMI: 4 Auxiliary Pressure Sensor Input 1 Circuit - Voltage Above Normal, or Shorted to High Source. High signal voltage detected at the OEM pressure circuit. you can visit the category Cumminz.
Leave a Reply
RELATED POSTS