Cummins ISL CM850 (2003-06) Fault Code: 499 PID: 98 SPN: 98 FMI: 4 Engine Oil Level Sensor Circuit - Voltage Below Normal or Shorted to Low Source. The engine oil level sensor has detected an internal failure.

Cummins ISL CM850 (2003-06) Fault Code: 499 PID: 98 SPN: 98 FMI: 4 Engine Oil Level Sensor Circuit - Voltage Below Normal or Shorted to Low Source. The engine oil level sensor has detected an internal failure.

Possible causes:

1)Open or short circuit internally to the oil level sensor
2)A failed oil level sensor
3)An open circuit in the oil level sensor circuit.

Possible repairs:

1)Replace the oil level sensor.
2)Replace the engine harness.
3)Replace the ECM.
4)The removal and installation of the connector may correct the fault.

If you want to know other articles similar to Cummins ISL CM850 (2003-06) Fault Code: 499 PID: 98 SPN: 98 FMI: 4 Engine Oil Level Sensor Circuit - Voltage Below Normal or Shorted to Low Source. The engine oil level sensor has detected an internal failure. you can visit the category Cumminz.