Cummins ISM CM870 (2003-06) Fault Code: 223 PID: S085 SPN: 1265 FMI: 4/4 Centinel? oil control valve circuit - shorted low. Low signal voltage detected at Centinel? oil control valve circuit.
This fault is logged when the ECM commands the Centinel? oil control valve ON and detects a lower signal voltage than expected at the output.
Possible causes:
1)Short circuit to ground in the oil control valve or engine harness.
2)Faulty ECM circuit
3)Low internal resistance of Centinel? oil control valve.
Possible repairs:
1)Replace the Centinel? oil control valve.
2)Replace the ECM.
3)Repair or replace the engine harness.
Cummins ISM CM870 (2003-06) Fault Code: 222 PID: P108 SPN: 108 FMI: 4/4 Barometric Pressure Sensor Circuit - Voltage Below Normal or Shorted to Low Source. Low signal voltage detected at barometric pressure circuit.
Cummins ISM CM870 (2003-06) Fault Code: 221 PID: P108 SPN: 108 FMI: 3/3 Barometric Pressure Sensor Circuit - Voltage Above Normal or Shorted to High Source. High signal voltage detected at barometric pressure circuit.
Cummins ISM CM870 (2003-06) Fault Code: 219 PID: P017 SPN: 1380 FMI: 1/17 Engine Oil Level Number 2 (Remote) Low - Maintenance. Low oil level detected in the Centinel? makeup oil tank.
Cummins ISM CM870 (2003-06) Fault Code: 214 PID: P175 SPN: 175 FMI: 0/0 Engine Oil Temperature - Data Valid But Above Normal Operating Range - Most Severe Level. Engine oil temperature signal indicates engine oil temperature above engine protection critical limit.