Cummins ISM CM870 (2003-06) Fault Code: 387 PID: S221 SPN: 1043 FMI: 3/3 Accelerator Pedal Position Sensor Supply Voltage Circuit - shorted high. High voltage detected at sensor supply circuit for the accelerator pedal position sensor.
This fault is logged when the ECM senses more than 5.25 volts on the accelerator pedal position +5 volt supply line. This can be caused by a short circuit to a voltage source in the OEM harness or a short circuit to an actuator signal circuit that is greater than +5 VDC.
Possible repairs:
1)Repair or replace the OEM harness.
2)Replace the ECM.
Cummins ISM CM870 (2003-06) Fault Code: 386 PID: S232 SPN: 1079 FMI: 3/3 Sensor Supply 1 Circuit - Voltage Above Normal or Shorted to High Source. High voltage detected at sensor supply number 1 circuit.
Cummins ISM CM870 (2003-06) Fault Code: 352 PID: S232 SPN: 1079 FMI: 4/4 Sensor Supply 1 Circuit - Voltage Below Normal or Shorted to Low Source. Low voltage detected at sensor supply number 1 circuit.
Cummins ISM CM870 (2003-06) Fault Code: 343 PID: S254 SPN: 629 FMI: 12/12 Electronic Control Module Warning Internal Hardware Failure - Bad Intelligent Device or Component. ECM power supply errors have been detected.
Cummins ISM CM870 (2003-06) Fault Code: 341 PID: S253 SPN: 630 FMI: 2/2 Engine control module (ECM) data lost.
If you want to know other articles similar to Cummins ISM CM870 (2003-06) Fault Code: 387 PID: S221 SPN: 1043 FMI: 3/3 Accelerator Pedal Position Sensor Supply Voltage Circuit - shorted high. High voltage detected at sensor supply circuit for the accelerator pedal position sensor. you can visit the category Cumminz.