Detroit DD13 EPA07 (2007-09) Fault Code: SPN 3696 FMI 13 (CPC) Diesel Particulate Filter Regen Force MUX Switch Message Contains SNV Indicator
DESCRIPTION:
Signal not available on the CPC DPF switch source address.
MONITORED PARAMETER:
CM1 DPF source add SAE J1939.
TYPICAL ENABLING CONDITIONS:
1. Key on
2. Engine off
EXECUTION FREQUENCY:
Continuous when enabling conditions met.
ENGINE REACTION:
None
VERIFICATION:
Cycle the key to power down, then cycle the key back on.
NOTE: Verify CPC group PGR001 parameter CM1 source add SAE J1939 is set to 49. If set properly, check other computers on the truck for faults.
Detroit DD13 EPA07 (2007-09) Fault Code: SPN 3695 FMI 19 (CPC) Diesel Particulate Filter Regeneration Inhibit Switch or Force Switch Message Contains a Data Error Indicator.
Detroit DD13 EPA07 (2007-09) Fault Code: SPN 3695 FMI 14 (CPC) Diesel Particulate Filter Regeneration Inhibit Switch or Force Switch Message Not Received This Ignition Cycle
Detroit DD13 EPA07 (2007-09) Fault Code: SPN 3695 FMI 13 (CPC) Diesel Particulate Filter Regeneration Inhibit Switch or Force Switch Message Contains Signal Not Valid Indicator
Detroit DD13 EPA07 (2007-09) Fault Code: SPN 3695 FMI 9 (CPC) Diesel Particulate Filter Regeneration Inhibit Switch or Force Switch Message Stopped Arriving