Detroit DD13 EPA07 (2007-09) Fault Code: SPN 701 FMI 4 (MCM, CPC) Digital Output 4 09 - Indicated by a Short to Ground on Pin 9 Circuit of the Common Powertrain Controller #4 Connector
NOTE: The CPC digital outputs have the same SPN as some motor control module (MCM) faults. The diagnostic service tool 7X makes the distinction between the MCM and CPC when diagnosing a fault.
NOTE: If engine is programmed correctly, failure is a short to ground on pin 9 of the CPC4 connector.
Detroit DD13 EPA07 (2007-09) Fault Code: SPN 698 FMI 5 (MCM) Grid Heater Circuit Failed Open
Detroit DD13 EPA07 (2007-09) Fault Code: SPN 679 FMI 7 (MCM) Pressure Limiting Valve (PLV) Staying Open
Detroit DD13 EPA07 (2007-09) Fault Code: SPN 677 FMI 31 (MCM, CPC) Starter Jammed (Tooth to Tooth Jam)
Detroit DD13 EPA07 (2007-09) Fault Code: SPN 677 FMI 18 (MCM, CPC) Starter Relay - Low Resistance