Detroit DD15 EPA10 (2010-13) Fault Code: SPN 1639 FMI 2 (MCM) Fan Speed Error
DESCRIPTION:
This code sets when a fan speed deviation is detected.
MONITORED PARAMETER:
Fan speed sensor.
TYPICAL ENABLING CONDITIONS:
Always enabled
MONITOR SEQUENCE:
None
EXECUTION FREQUENCY:
Always enabled
TYPICAL DURATION:
Two seconds
DASH LAMPS:
CEL
ENGINE REACTION:
None
VERIFICATION:
Engine running with fan engaged.
NOTE: If 1071-5 or 647-5 active, repair the wiring between pin 91 (from the 120 pin ECM connector) and the fan and the jake brake solenoids.
PROBABLE CAUSES:
1. Coolant loss.
2. Thermostat failure.
3. Blockage in radiator and charge air cooler.
4. Fan belt condition.
5. Proper location of fan shroud.
6. Proper radiator hose condition.
7. Fan failure.
8. Short between fan speed sensor and ECM.
9. Fan drive failure.
If you want to know other articles similar to Detroit DD15 EPA10 (2010-13) Fault Code: SPN 1639 FMI 2 (MCM) Fan Speed Error you can visit the category DD15 EPA10 (2010-13).