Detroit DD15 EPA10 (2010-13) Fault Code: SPN 3480 FMI 16 (MCM) High Hydrocarbon Doser Supply Pressure High
NOTE: The code occurs when the cut off is commanded to 100% and the compensation pressure is greater than 95 psi.
NOTE: If there are any other fuel system codes or 3480-14 present, fix those first.
PROBABLE CAUSES:
1. Failed doser pressure control valve in the high pressure flange.
2. Perform parked regen.
Detroit DD15 EPA10 (2010-13) Fault Code: SPN 3480 FMI 14 (MCM) Hydrocarbon Doser Fuel Line Pressure Sensor - Failed Self Test
Detroit DD15 EPA10 (2010-13) Fault Code: SPN 3480 FMI 4 (MCM) Fuel Compensation Pressure Sensor Circuit Failed Low
Detroit DD15 EPA10 (2010-13) Fault Code: SPN 3480 FMI 3 (MCM) Fuel Compensation Pressure Sensor Circuit Failed High
Detroit DD15 EPA10 (2010-13) Fault Code: SPN 3480 FMI 2 (MCM) Hydrocarbon Doser Fuel Line Pressure Low
If you want to know other articles similar to Detroit DD15 EPA10 (2010-13) Fault Code: SPN 3480 FMI 16 (MCM) High Hydrocarbon Doser Supply Pressure High you can visit the category DD15 EPA10 (2010-13).