Detroit DD16 EPA10 (2010-13) Fault Code: SPN 3512 FMI 4 (MCM) 3V Sensor Supply Bank 2 Circuit Failed Low
NOTE: This code indicated a motor control module (MCM) internal failure. Replace the MCM.
DESCRIPTION:
3V Sensor supply bank 2 circuit failed low.
MONITORED PARAMETER:
MCM 3V internal power supply.
TYPICAL ENABLING CONDITIONS:
Always enabled
MONITOR SEQUENCE:
None
EXECUTION FREQUENCY:
Always enabled
TYPICAL DURATION:
Two seconds
DASH LAMPS:
1. MIL
2. CEL
VERIFICATION:
Engine Idle: One minute.
NOTE: This code always indicates to replace the MCM.
Detroit DD16 EPA10 (2010-13) Fault Code: SPN 3511 FMI 4 (MCM) 3V Sensor Supply Bank 1 Circuit Failed Low
Detroit DD16 EPA10 (2010-13) Fault Code: SPN 3511 FMI 3 (MCM) 3V Sensor Supply Bank 1 Circuit Failed High
Detroit DD16 EPA10 (2010-13) Fault Code: SPN 3510 FMI 8 (CPC) 2-Channel Accelerator Pedal Supply Voltage Missing
Detroit DD16 EPA10 (2010-13) Fault Code: SPN 3510 FMI 7 (CPC) Accelerator Pedal Sensor Failed High