Detroit DD16 EPA10 (2010-13) Fault Code: SPN 3598 FMI 3 (MCM) Proportional Valve Bank 2 Circuit Failed High
DESCRIPTION:
Proportional valve bank 2 circuit failed high.
MONITORED PARAMETER:
Motor control module (MCM) bank 2 power.
TYPICAL ENABLING CONDITIONS:
Always enabled
MONITOR SEQUENCE:
None
EXECUTION FREQUENCY:
Always enabled
TYPICAL DURATION:
Two seconds
DASH LAMPS:
1. MIL
2. CEL
VERIFICATION:
Engine Idle: One minute.
PROBABLE CAUSES:
1. Short to power between pin 2 of the rear Jake brake solenoid and pin 62 of the MCM 120-pin connector.
2. Short to power between pin 2 of the Electronic Dosing Valve and pin 64 of the MCM 120-pin connector.
3. Failed MCM (Engine ECM).