Detroit DD16 EPA10 (2010-13) Fault Code: SPN 411 FMI 3 (MCM) Exhaust Gas Recirculation Delta P Sensor Circuit Failed High
DESCRIPTION:
EGR Delta Pressure Sensor Circuit High.
MONITORED PARAMETER:
EGR delta pressure sensor.
TYPICAL ENABLING CONDITIONS:
Always enabled
MONITOR SEQUENCE:
None
EXECUTION FREQUENCY:
Always enabled
TYPICAL DURATION:
2 seconds
DASH LAMPS:
1. CEL
2. MIL
ENGINE REACTION:
Derate 25%
VERIFICATION:
Engine Idle: One minute.
PROBABLE CAUSES:
1. EGR delta p sensor failure.
2. EGR delta p connector/harness.
3. EGR delta p pressure ports blocked.
Detroit DD16 EPA10 (2010-13) Fault Code: SPN 411 FMI 3 (MCM) EGR Delta Pressure Sensor Circuit Failed High
Detroit DD16 EPA10 (2010-13) Fault Code: SPN 411 FMI 2 (MCM) Exhaust Gas Recirculation Delta P Sensor Out of Calibration
Detroit DD16 EPA10 (2010-13) Fault Code: SPN 411 FMI 1 (MCM) EGR Differential Pressure Failed (High Box)
Detroit DD16 EPA10 (2010-13) Fault Code: SPN 411 FMI 0 (MCM) Exhaust Gas Recirculation Differential Pressure is Too High at Low Speeds and Loads