Detroit DD16 EPA10 (2010-13) Fault Code: SPN 4193 FMI 4 (MCM) Engine Coolant Inlet Temperature Circuit Failed Low
DESCRIPTION:
Engine coolant inlet temperature circuit failed low.
MONITORED PARAMETER:
Engine coolant inlet temperature sensor.
TYPICAL ENABLING CONDITIONS:
Always enabled
MONITOR SEQUENCE:
None
EXECUTION FREQUENCY:
Always enabled
TYPICAL DURATION:
Two seconds
DASH LAMPS:
1. MIL
2. CEL
VERIFICATION:
Engine Idle: One minute.
NOTE: If there are any cooling system faults or conditions, repair those first.
PROBABLE CAUSES:
1. Inlet coolant temperature sensor.
1. Inlet coolant temperature sensor connector/harness.
Detroit DD16 EPA10 (2010-13) Fault Code: SPN 4193 FMI 3 (MCM) Engine Coolant Inlet Temperature Circuit Failed High
Detroit DD16 EPA10 (2010-13) Fault Code: SPN 4193 FMI 2 (MCM) Coolant Inlet Temperature Not Plausible
Detroit DD16 EPA10 (2010-13) Fault Code: SPN 4100 FMI 13 (MCM, ACM) Motor Control Module or the Aftertreatment Control Module Software Not Compatible
Detroit DD16 EPA10 (2010-13) Fault Code: SPN 4077 FMI 14 (MCM) Hydrocarbon Doser Fuel Line Pressure Failed Self - Test