Detroit DD16 EPA10 (2010-13) Fault Code: SPN 4334 FMI 2 (ACM) Diesel Exhaust Fluid Metering Unit Pressure Sensor - Drift
DESCRIPTION:
Diesel exhaust fluid (DEF) pressure sensor - drift.
MONITORED PARAMETER:
Diesel exhaust fluid (DEF) pressure.
TYPICAL ENABLING CONDITIONS:
Pressure limiting unit off.
MONITOR SEQUENCE:
Five hour engine off time.
EXECUTION FREQUENCY:
Continuous when enabling conditions met.
TYPICAL DURATION:
Five seconds
DASH LAMPS:
MIL
VERIFICATION:
SCR quantity test.
PROBABLE CAUSES:
1. DEF metering unit pressure sensor.
2. DEF metering unit pressure sensor connector/harness.
3. Flush DEF metering system.
Detroit DD16 EPA10 (2010-13) Fault Code: SPN 4258 FMI 4 (MCM) Injector Amplifier Control Valve Cylinder 4, 5, 6 Shorted to Ground
Detroit DD16 EPA10 (2010-13) Fault Code: SPN 4258 FMI 3 (MCM) Injector Amplifier Control Valve Cylinder 4, 5, 6 Shorted to Battery
Detroit DD16 EPA10 (2010-13) Fault Code: SPN 4257 FMI 4 (MCM) Injector Amplifier Control Valve Cylinder 1, 2, 3 Shorted to Ground
Detroit DD16 EPA10 (2010-13) Fault Code: SPN 4257 FMI 3 (MCM) Injector Amplifier Control Valve Cylinder 1, 2, 3 Shorted to Battery
If you want to know other articles similar to Detroit DD16 EPA10 (2010-13) Fault Code: SPN 4334 FMI 2 (ACM) Diesel Exhaust Fluid Metering Unit Pressure Sensor - Drift you can visit the category DD16 EPA10 (2010-13).