DESCRIPTION:
CPC Output 4 07 Short to Voltage.
MONITORED PARAMETER:
CPC output 4/7.
TYPICAL ENABLING CONDITIONS:
Always enabled
MONITOR SEQUENCE:
None
EXECUTION FREQUENCY:
Always enabled
TYPICAL DURATION:
Two seconds
DASH LAMPS:
CEL
ENGINE REACTION:
None
VERIFICATION:
Engine on with output activation.
PROBABLE CAUSES:
Wiring problem between pin 1 and/or 3 of the turbocharger actuator connector and pin 35 of the 120-pin ECM connection.