Eaton Fuller Advantage (2017) Fault Code: 29 PID: SID 372 SPN: FMI: 5 Remote Throttle Enable: Current Below Normal or Open Circuit
Overview:
The Fuller Advantage transmission is equipped with a relay circuit that allows the throttle of the engine to be located in a remote location. The relay and associated wiring are installed by the OEM. Fault Code 29 sets when the Transmission Electronic Control Unit (TECU) detects an open or a shorted condition in the wiring between the TECU and the relay.
Detection:
The TECU monitors the remote throttle enable circuit for opens or shorts. If either condition is present for 1 second or greater, the fault is set Active.
Conditions to Set Fault Code Active:
FMI 5 Current Below Normal or Open Circuit: TECU detects an open circuit or excessive resistance in the circuit.
Fallback:
Remote throttle will not function.
Conditions to Set Fault Code Inactive:
All FMIs: Short or open condition is not detected by the TECU for 2 seconds.
Possible Causes:
FMI 4, 5
1) Vehicle Harness
- Bent, spread, loose or corroded terminals
- Wiring shorted to ground or open
2) Remote Throttle Relay
- Internal failure
3) TECU
- Internal failure