Eaton Fuller Advantage (2017) Fault Code: 34 PID: SPN: 168 FMI: 14 Weak Battery Voltage Supply: Special Instructions
Overview:
Fault Code 34 sets Active if battery voltage to the TECU falls below 9 volts for more than 10 seconds.
Detection:
The TECU monitors the battery voltage supplied to the TECU after completing the power-up sequence. Fault Code 34 sets Active if battery voltage to the TECU falls below 9 volts for more than 10 seconds. Fault Code 33, Low Battery Voltage Supply, represents a more severe drop in battery voltage than Fault Code 34.
Conditions to Set Fault Code Active:
FMI 14 Special Instructions: TECU monitors the battery voltage of the vehicle. If the voltage falls below 9 volts for more than 10 seconds, the fault sets Active.
Fallback:
FMI 14
Engine may not crank.
Transmission may not engage a gear from neutral.
Transmission may not attempt to shift.
Until the fault becomes Inactive, driver may have to shut off engine with transmission in gear.
Conditions to Set Fault Code Inactive:
FMI 14: Battery voltage stays at 9 volts or greater for at least 20 seconds.
Possible Causes:
FMI 14
1) Vehicle Power Supply
- Wiring shorted to ground, shorted to power or open
- Bent, spread, corroded or loose terminals
- In-line fuse corrosion, loose connection or blown fuse
2) Vehicle Batteries
- Internal failure
3) Vehicle Charging System
- Charging system failed
4) TECU
- Internal failure
If you want to know other articles similar to Eaton Fuller Advantage (2017) Fault Code: 34 PID: SPN: 168 FMI: 14 Weak Battery Voltage Supply: Special Instructions you can visit the category DTC TRUCKS.