Isuzu 4HE1 (1999-04) P13
Isuzu 4HE1 (1999-04) P13 ECT Sensor Circuit High
Error Classified:
Water Temp Sensor - Harness Open +B short
Diagnostic Condition:
-79°C (390kΩ) or lower, or 120°C (115kΩ) or higher detected.
Return Condition:
When Forward Normal
Back Up:
EVRV: EGR
VSV: EGR Quick Cut
VSV: VSS
MV: Timing Advance.
The above outputs stop.
VSV: ANECON is actuated
QOS: 0°C or lower control
Judging Time:
0.52 sec