Isuzu 4HE1 (1999-04) P21 Rack Sensor Circuit Low
Isuzu 4HE1 P21
Error Classified:
Rack Sensor - Harness Open GND short
Diagnostic Condition:
Rack Voltage 0.3V or lower, Engine speed 600-900rpm, and water Temp. 0掳C or higher are detected for 3 sec running.
Return Condition:
When forward normal
Back Up:
EVRV: EGR
VSV: EGR Quick Cut
VSV: VSS The above outputs stop
R/L: QWS Non-continuity idle position output stop.
The above outputs stop.
Rack learning valve: 0
Judging Time:
3.52 sec
If you want to know other articles similar to Isuzu 4HE1 (1999-04) P21 Rack Sensor Circuit Low you can visit the category ISUZU.